Part Number |
HK-2 |
Size |
8.85 in (22.3 cm) wide
11.65 in (29.6 cm) high
8.55 in (21.7 cm) deep |
Weight |
6 lbs (2.7 kg) |
Power |
12 to 24 VDC or 12 to 24 VAC 50-60 Hz, 7 watts |
Temperature Range |
14˚F to 140˚F (-10˚C to 60˚C) non-operating/storage
32˚F to 113˚F (0˚C to 45˚C) operating |
Relative Humidity
(non-condensing) |
5% to 85% non-operating/storage
20% to 80% operating |
Verification Time |
Less than one second |
Memory Retention |
Up to 5 years via the standard internal lithium battery. |
Transaction Storage |
5120 transactions |
ID Number Length |
1 to 10 digits from keypad or card |
User Capacity |
512 users expandable to 32,512 users |
Template Size |
9 bytes |
Communications |
RS-485 (4 and 2 wire)
RS-232 Serial Printer Support or network communications |
Baud Rate |
300 to 28.8 Kbps |
Card Reader Input |
Proximity, Wiegand, Magnetic Stripe, Bar Code
(5 VDC provided by HandReader) |
Card Reader Output |
Wiegand, Magnetic Stripe, Bar Code |
Duress Code |
1 leading digit (user definable) |
Door Controls |
Request to Exit input (switch or keypad), Door Switch input, Door Lock output.
(open collector, 5 VDC present, sinks to ground, 100 mA max) |
Alarm Monitoring |
Tamper, Door Forced, Duress |
Event Monitoring |
There are a variety of monitoring options including events such as: Invalid ID, Time Zone Violation, ID Refused, Try Again, Power Failure |
Time Zones |
62 user definable time zones
Unlimited holidays |
Auxiliary Outputs |
3 user definable
(open collector, 5 VDC present, sinks to ground, 100 mA max) |
Auxiliary Inputs |
2 user definable
(open collector, 5 VDC present, sinks to ground, 100 mA max) |
Options |
BB-200 |
Operational Battery Backup |
CR-2 |
Magnetic Stripe Card Reader Wall Mount |
DC-102 |
Data Converter |
EM-801 |
Memory Expansion - 9,728 users |
EM-803 |
Memory Expansion - 32,512 users |
EN-200 |
Ethernet Communications Module |
KP-201 |
Auxiliary Keypad |
MD-500 |
High Speed Internal Modem |
PROX |
HID Proximity Reader |
WAR-EXT |
1 year extended warranty |
|